The quality and safety of the built environment have to be assessed and made visible. Nuvap’s solutions are able to provide insights and analytics about indoor environmental quality. Information and services provided by Nuvap enable IAQ management and facilitate the reporting within quality/ wellbeing certification and sustainability frameworks (ISO45000, WELL, ESG,…).

Categories: ,

Description

Technical Details
Specifications

Dimensions 183x183x80mm
Operating Temperature -5°C to +40°C
Storage Temperature -5°C to +40°C
Operating Humidity 20% to 80% non condensing
Storage Humidity 20% to 80% non condensing
Deployment Indoor

Operations

Battery Back-up 2 hours
Power Supply Input 100/220V, 50-60Hz
Power Supply Output 5 Vdc 2A

Connectivity
WiFi 2.4 GHz 802.11 b/g WPA PSK;
LTE Cat M1/Cat NB1/EGPRS 850/900/1800/1900MHz
BTLE – only for configuration purpose;

Factor Working Range Resolution
Carbon Dioxide(CO2) 0-5.000 ppm 50 ppm
Carbon Monoxide(CO) 0-5.000 ppm 1 ppm
Formaldehyde(CH2O) 0-10 ppm 0,5 ppm
Nitrogen Dioxide(NO2) 0-30 ppm 0,1 ppm
Ozone(O3) 0-5 ppm 0,5 ppm
PM1 | PM2,5 | PM10 0-1000ug/m3 1 ug/m3
Relative Humidity 0-100 %Rh 1%Rh
Temperature -40 – +120°C 0,1°C
TVOC 0-60.000 ppb 1-32 ppb

Frequently Asked Questions

How to configure Nuvap devices?

The device acquires the information from the Wi-Fi network when it is switched on; it is therefore extremely important to switch it on and configure it in an area with a good network coverage.

  1. Login from the Mobile App with the credentials provided by the Nuvap account.
  2. Select ‘Manage N1s’ from the menu
  3. Select ‘Add Device’
  4. Scan the QRCODE that is at the bottom of the device to be configured
  5. Follow the guided configuration procedure from the Nuvap App

Is it possible to move the device, after its first installation?

Yes, it is possible. It might happen that moving the device it loses the wifi connectivity. In this case, in order to upload the stored data from the device to the cloud platform, either the device is registered on a new wifi network or it needs to go back under the previous wifi network coverage.

Where are Nuvap devices to be placed?

Nuvap devices are desktop mounted. The devices must be installed between 1.1-1.7 m above the floor, in places where occupants usually stay. They have to be at least 1 meter away from doors, windows and air / exhaust vents.